top of page
2020-REV.png

PHYSICAL ADDRESS

10433 Success Street

Ashland, VA 23005

 

Office: (804) 752-4888

Fax: (804) 752-4885

Rental 30 HP Hurst Modular Boiler Plant

Unit #: RB-H30-G Plant Dimensions: 8’W x20’L x 8’6”H

Boiler Specifications:

30 HP High Pressure Hurst Vertical Steam Boiler:

Model #: VT-G-30-150

Serial #: V86-150-619

N.B. #:20624

Job#:1501070

Max W.P.150 PSI

HTG.Surf.Sq.Ft.86

Steam Ib/hr:1053

Min:650,000 BTU/ HR

Max:1,260,000 BTU / HR

Year:2015

Electrical Requirements:

UL Tag: Gas Fired Boiler Assembly No. AR-751855

For use with 6 Primary safety controls

 

Feed Water Tank Specifications:

Model: N/A

Serial: 

Electrical Requirements:  

 

Water Softener:

Model:  AT-948NA-25T

Serial:  18J84884

Electrical Requirements:  120v

 

Required Field Connections:

Main Steam:  2” NPT

Condensate Return: 1 ¼” NPT

Natural Gas Pipe:  1 ¼” NPT

Make-Up Water:  ¾” NPT

Blow-Down:  2 ½” NPT

Flue Pipe:  Included Loose

Safety Relief:  1” NPT

Electrical Service to Panel:  230V / 1PH / 30Amps

30hp_rental.png

Rental 100 HP Cleaver-Brooks Modular Boiler Plant

Unit #: RB-L100-G Plant Dimensions: 8’W x40’L x 8’6”H

Boiler Specifications:

100 HP Low Pressure Cleaver-Brooks Steam Boiler:

Model #: CB700-100-15

Serial #: L

N.B. #:

Job#:

Max W.P.15 PSI

HTG.Surf.Sq.Ft.

Steam Ib/hr:

Min: BTU/ HR

Max: BTU / HR

Year:

Electrical Requirements:

 

Feed Water Tank Specifications:

Model: 

Serial:

Electrical Requirements:

 

Water Softener:

Model:

Serial:

Electrical Requirements:  120v

 

Required Field Connections:

Main Steam:  6” 150# Flanged

Condensate Return: 2” NPT

Natural Gas Pipe:

Make-Up Water:  ¾” NPT

Blow-Down:  1 ½” NPT

Flue Pipe:  Included Loose

Safety Relief:

Electrical Service to Panel:  230V / 3PH / 60Amps

100hp_CB_rental (2).jpeg

Rental 200 HP Superior Modular Boiler Plant

Unit #: RB-H200-GO Plant Dimensions: 8’W x40’L x 9’6”H

Boiler Specifications:

200 HP High Pressure 2 pass Superior Steam Boiler:

Model #: 8-5-1000-S150-PF-GA2

Serial #: 18921

N.B. #:18921

Job#:19090341

Max W.P.150 PSI

HTG.Surf.Sq.Ft.1013

Steam Ib/hr:6900

Min:  3,000,000  BTU/ HR

Max:8,400,000 BTU / HR

Year:2018

Electrical Requirements:

 

Feed Water Tank Specifications:

Model:  G5115BX-5D Duplex

Serial:  19-444-B

Electrical Requirements: 

 

Water Softener:

Model:  AT-948NA-25T

Serial:  18J84884

Electrical Requirements: 120v

 

Required Field Connections:

Main Steam:  6” 150# Flanged

Condensate Return: 4” 150# Flanged

Natural Gas Pipe: 1 ½” NPT

Make-Up Water:  ¾” NPT

Blow-Down:  1 ¼” NPT

Flue Pipe:  Included Loose

Relief Piping:  2” NPT

Electrical Service to Panel:  230V / 3PH / 60Amps

200hp_rental.png

Rental 500 HP Kewanee Modular Boiler 

Unit #: RB-H500-GO Dimensions: 8’W x48’L x 13’4”H

500hp_kewanee_rental.png

Boiler Specifications:

500 HP High Pressure Kewanee Steam Boiler:

Model #: 

Serial #: 

N.B. #:42619

Job#:

Max W.P.150 PSI

HTG.Surf.Sq.Ft.

Steam Ib/hr:

Min: BTU/ HR

Max: BTU / HR

Year:1990

Electrical Requirements:

 

Feed Water Tank Specifications:

Model:  N/A

Serial:

Electrical Requirements:

 

Water Softener:

Model #:  N/A

Serial #:

Electrical Requirements: 

 

Required Field Connections:

Main Steam:  8” 300# Flanged

Condensate Return: N/A

Natural Gas Pipe: 3” Flanged  (Required Inlet Pressure 3-7 PSI)

Oil Supply:  1” NPT

Feed Water:  2” Flanged

Blow-Down:  2” Flanged

Flue Pipe:  Included Loose

Relief Piping:  2 ½” NPT

Electrical Service To Panel:  V / PH / Amps

**Rental Boiler Plants Are Piped and Ready For Field Piping / Electrical To Required Connections.

Units Are Provided With Necessary Flue Piping. Temporary Piping And Electrical Cable are Not Included.

bottom of page