Rental 30 HP Hurst Modular Boiler Plant
Unit #: RB-H30-G Plant Dimensions: 8’W x20’L x 8’6”H
Boiler Specifications:
30 HP High Pressure Hurst Vertical Steam Boiler:
Model #: VT-G-30-150
Serial #: V86-150-619
N.B. #:20624
Job#:1501070
Max W.P.150 PSI
HTG.Surf.Sq.Ft.86
Steam Ib/hr:1053
Min:650,000 BTU/ HR
Max:1,260,000 BTU / HR
Year:2015
Electrical Requirements:
UL Tag: Gas Fired Boiler Assembly No. AR-751855
For use with 6 Primary safety controls
Feed Water Tank Specifications:
Model: N/A
Serial:
Electrical Requirements:
Water Softener:
Model: AT-948NA-25T
Serial: 18J84884
Electrical Requirements: 120v
Required Field Connections:
Main Steam: 2” NPT
Condensate Return: 1 ¼” NPT
Natural Gas Pipe: 1 ¼” NPT
Make-Up Water: ¾” NPT
Blow-Down: 2 ½” NPT
Flue Pipe: Included Loose
Safety Relief: 1” NPT
Electrical Service to Panel: 230V / 1PH / 30Amps

Rental 100 HP Cleaver-Brooks Modular Boiler Plant
Unit #: RB-L100-G Plant Dimensions: 8’W x40’L x 8’6”H
Boiler Specifications:
100 HP Low Pressure Cleaver-Brooks Steam Boiler:
Model #: CB700-100-15
Serial #: L
N.B. #:
Job#:
Max W.P.15 PSI
HTG.Surf.Sq.Ft.
Steam Ib/hr:
Min: BTU/ HR
Max: BTU / HR
Year:
Electrical Requirements:
Feed Water Tank Specifications:
Model:
Serial:
Electrical Requirements:
Water Softener:
Model:
Serial:
Electrical Requirements: 120v
Required Field Connections:
Main Steam: 6” 150# Flanged
Condensate Return: 2” NPT
Natural Gas Pipe:
Make-Up Water: ¾” NPT
Blow-Down: 1 ½” NPT
Flue Pipe: Included Loose
Safety Relief:
Electrical Service to Panel: 230V / 3PH / 60Amps
.jpeg)
Rental 200 HP Superior Modular Boiler Plant
Unit #: RB-H200-GO Plant Dimensions: 8’W x40’L x 9’6”H
Boiler Specifications:
200 HP High Pressure 2 pass Superior Steam Boiler:
Model #: 8-5-1000-S150-PF-GA2
Serial #: 18921
N.B. #:18921
Job#:19090341
Max W.P.150 PSI
HTG.Surf.Sq.Ft.1013
Steam Ib/hr:6900
Min: 3,000,000 BTU/ HR
Max:8,400,000 BTU / HR
Year:2018
Electrical Requirements:
Feed Water Tank Specifications:
Model: G5115BX-5D Duplex
Serial: 19-444-B
Electrical Requirements:
Water Softener:
Model: AT-948NA-25T
Serial: 18J84884
Electrical Requirements: 120v
Required Field Connections:
Main Steam: 6” 150# Flanged
Condensate Return: 4” 150# Flanged
Natural Gas Pipe: 1 ½” NPT
Make-Up Water: ¾” NPT
Blow-Down: 1 ¼” NPT
Flue Pipe: Included Loose
Relief Piping: 2” NPT
Electrical Service to Panel: 230V / 3PH / 60Amps

Rental 500 HP Kewanee Modular Boiler
Unit #: RB-H500-GO Dimensions: 8’W x48’L x 13’4”H

Boiler Specifications:
500 HP High Pressure Kewanee Steam Boiler:
Model #:
Serial #:
N.B. #:42619
Job#:
Max W.P.150 PSI
HTG.Surf.Sq.Ft.
Steam Ib/hr:
Min: BTU/ HR
Max: BTU / HR
Year:1990
Electrical Requirements:
Feed Water Tank Specifications:
Model: N/A
Serial:
Electrical Requirements:
Water Softener:
Model #: N/A
Serial #:
Electrical Requirements:
Required Field Connections:
Main Steam: 8” 300# Flanged
Condensate Return: N/A
Natural Gas Pipe: 3” Flanged (Required Inlet Pressure 3-7 PSI)
Oil Supply: 1” NPT
Feed Water: 2” Flanged
Blow-Down: 2” Flanged
Flue Pipe: Included Loose
Relief Piping: 2 ½” NPT
Electrical Service To Panel: V / PH / Amps